Non-Tapered Piles
H-PILE
The following input parameters are required for defining an H-Pile:
- Type of H-Pile - users can select from 11 pre-defined piles
- Pile Perimeter for Analysis - This is the perimeter that will be used for the skin friction capacity computations. The two options are H Pile Perimeter and Box Perimeter.
- Tip Area for Analysis - This is the bottom area of the pile that will be used for end bearing capacity calculations. The three options are H Pile Area, Box Area, and User Select.
The table below summarizes the properties of the available H-Pile sections.
METRIC
H-Pile Designation | Pile Area (mm2) | Width (mm) | Perimeter (mm) | Box Area (mm2) | Box Perimeter (mm) |
HP 360x174 | 22 200 | 378 | 2153 | 136 468 | 1478 |
HP 360x152 | 19 400 | 376 | 2140 | 133 856 | 1464 |
HP 360x132 | 16 900 | 373 | 2122 | 130 923 | 1448 |
HP 360x108 | 13 800 | 370 | 2106 | 128 020 | 1432 |
HP 310x125 | 15 800 | 312 | 1805 | 97 344 | 1248 |
HP 310x110 | 14 000 | 310 | 1793 | 95 480 | 1236 |
HP 310x93 | 11 800 | 308 | 1780 | 93 324 | 1222 |
HP 310x79 | 9 970 | 306 | 1768 | 91 494 | 1210 |
HP 250x85 | 10 800 | 260 | 1491 | 66 040 | 1028 |
HP 250x62 | 7 980 | 256 | 1467 | 62 976 | 1004 |
HP 200x53 | 6 810 | 207 | 1190 | 42 228 | 822 |