Tapered Piles
PIPE PILE - OPEN END
The following are required for the open-end pipe pile:
- Diameter of Pile - outside diameter
- Shell Thickness - wall thickness
CONCRETE PILE
The input required for a concrete pile is the Side of Square Section.
PIPE PILE CLOSE-ENDED, TIMBER PILE, RAYMOND AND MONOTUBE
The only input required for these cross-sections is the pile diameter
Note:
- Any cross section can be made tapered in the Pile type Editor Except for H-Pile
- Monotubes can be modeled (similar to v3.005) by selecting Pipe Pile – Closed End
- With reference to chart 2.1.1.3, of the theory manual:
- The uniform section of Pile-Pipe closed end will use curve a
- The tapered section of Pile-Pipe closed end will use curve g
- The uniform section of a Raymond pile will use curve d
- The tapered section of a Raymond pile will use curve e