CPT Results Display
The CPT Interpretation results are displayed in two tabs by default, the Inputs and Results tabs.
For details on how to customize the chart displays, see the CPT Chart Controls topic.
For information on viewing the results of multiple CPT files at once, see the Viewing Multiple CPTs topic.
Inputs Tab
In the Inputs tab, the graphical display cannot be manipulated. The displayed graphs are:
- Cone Resistance
- Sleeve Resistance
- Pore Pressure
The tabular data can be modified using the Edit CPT Columns icon.
Results Tab
The graphs displayed in the Results tabs can be modified, and up to 5 graphs can be shown at one time. Use the following icons to customize the results views as desired.
Reorder CPT Charts | You can reorder the charts displayed in the top results pane in the CPT Chart Output dialog. Each Chart Output is a drop-down menu, with which you can modify the parameter displayed in each chart. Charts can be added or deleted from the display using the or icons. Charts can be reordered using the and icons. The Reset button is used to reset the charts to the default layout. |
View Mode
| Use the View Mode icon to hide and reveal the tabular data displayed in the bottom pane of the results window. |
Number Format | Change the number of displayed decimals, or set the display to Scientific Notation, in the Number Format dialog. |
Edit Columns
| Change the displayed tabular data. Any number of columns can be displayed. Use the and icons to reorder the columns. Use the Match to Charts button to match the tabular data columns to the charts displayed. |
Plot SBT Zone | Plot the SBT Zones. Use the Export Image button to export the SBT Zones graph. |
Custom Tabs
Custom results viewing tabs can also be added using the + icon.